When preparing for any phase of work on your wood home, remember a few simple principles:
- Carefully read all application instructions before you begin.
 
- Thoroughly clean all work surfaces. Choose your cleaners carefully. Contact Perma-Chink Systems for complete information.
 
- Apply products in moderate temperatures, out of direct sunlight.
 
- Allow all previous applications time to adequately dry before applying another coat.
 
- Better tools mean better results - don't skimp.
 
- Take your time and enjoy the process.
 
 
Appropriate uses for LIFELINE Products
NR = Not Recommended
 | 
Lifeline Ultra 7   Lifeline Endure | 
Lifeline Ultra-2  Lifeline Exterior  Lifeline Accents Exterior | 
Lifeline Advance | 
Lifeline Interior,   Accents Interior  | 
Acrylic Gloss / Satin  | 
Coverage   (depends on wood species) | 
first coat 350-450 sq.ft. per gallon;  second coat 600-800 sq.ft. per gallon | 
first coat 350-450 sq.ft. per gallon;  second coat 600-800 sq.ft. per gallon | 
800-1000 sq.ft. per gallon over LIFELINE stain | 
first coast 350-450 sq.ft. per gallon;  second coat 600-800 sq.ft. per gallon | 
500 sq.ft. per gallon | 
Exterior   Walls | 
1 coat | 
2 coats | 
multiple coats over LIFELINE stains | 
Never | 
Never | 
| Soffits | 
1 coat | 
2 coats | 
multiple coats over LIFELINE stains | 
Never | 
Never | 
| Facia | 
1 coat | 
2 coats | 
multiple coats over LIFELINE stains | 
Never | 
Never | 
| Decks | 
1 coat | 
Never | 
Never | 
Never | 
Never | 
Exterior   Trim | 
1 coat | 
2 coats | 
multiple coats over LIFELINE stains | 
Never | 
Never | 
Interior   Walls | 
NR | 
NR | 
NR | 
Build thin coats to achieve desired film | 
As Desired | 
Interior   Ceilings | 
NR | 
NR | 
NR | 
Build thin coats to achieve desired film | 
As Desired | 
Interior   Millwork | 
NR | 
NR | 
NR | 
1 coat to colour and seal | 
Build thin coats to achieve desired film | 
 
Appropriate use for SEALANTS 
NR = Not Recommended 
 | 
Perma-Chink | 
Energy Seal | 
Woodsman | 
Woodsman | 
Check Mate 2 | 
Coverage   (depends on wood species) | 
See table below | 
See table below | 
See table below | 
30 linear ft. per tube | 
Variable, depends on check width | 
| Horizontal Seams | 
On Chink-style homes | 
After stacking | 
Between logs  during stacking | 
NR | 
Never | 
| Corners | 
On Chink-style homes | 
External Sealant | 
Internal Sealant | 
NR | 
Never | 
| Windows & Doors | 
Energy Seal preferred | 
External Sealant | 
Internal Sealant | 
NR | 
Never | 
| Butt Joints | 
Energy Seal preferred | 
External Sealant | 
Internal Sealant | 
NR | 
Never | 
| Upward Facing Checks | 
NR | 
NR | 
Never | 
NR | 
Yes | 
| Kitchen & Bathroom Sealing | 
NR | 
NR | 
Never | 
Whenever caulk is needed | 
Never | 
 
ESTIMATED COVERAGE RATES 
| Perma-Chink Coverage Rates | 
 
| To be Applied 1/4" - 3/8" thickness. | 
 
| Width of gap | 
Feet per pail | 
 
| 1/2" | 
Use Energy Seal | 
 
| 3/4" | 
Use Energy Seal | 
 
| 1" | 
385' | 
 
| 1.5" | 
256' | 
 
| 2" | 
192' | 
 
| 2.5" | 
154' | 
 
| 3" | 
127' | 
 
| 3.5" | 
110' | 
 
| 4" | 
96' | 
 
| 4.5" | 
85' | 
 
| 5" | 
76' | 
 
| 6" | 
63.5' | 
 
 
 | 
| Energy Seal Coverage Rates | 
 
| To be applied 3/8" thickness | 
 
| Width of gap | 
Feet per tube 11-oz. | 
Feet per tube 30-oz. | 
Feet per pail | 
 
| 1/2" | 
16' | 
48' | 
975' | 
 
| 3/4" | 
11' | 
32' | 
650' | 
 
| 1" | 
8' | 
24' | 
490' | 
 
 
| Woodsman Coverage Rates | 
 
| Diameter of Bead | 
Feet per tube 11-oz. | 
Feet per tube 30-oz. | 
 
| 1/4" | 
32' | 
92' | 
 
| 3/8" | 
14' | 
41' | 
 
| 1/2" | 
8' | 
23' | 
 
 
 | 
 
Stains and Finishes Application Guide 
 
Application Guide for Lifeline stains and finishes
Log Home Sealant Application Guide 
 
Application Guide for Perma-Chink, Energy Seal, Stack-n-Seal